Develop pneumatic circuit to operate direct single acting cylinder

Instructions to run pneumatic circuit to operate direct single acting cylinder

  1. Select Operation as Direct control of single acting cylinder \
  2. Select the component (Hold down the Ctrl (windows) or Command (Mac) button to select multiple options) as single acting cylinder return by spring and 3/2 DC Valve normally closed. \
  3. Select method of actuation as Manually actuated. \
  4. Click on check configuration. If it is correct the next level button is activated. Clcik on Next level button. \
  5. On the left side you will see the library of components required to build the diagram and on the right side you will see the Workspace. \
  6. Point the mouse cursor to any component in library you will see the name of component. \
  7. Simply left click mouse button on component and drag it to the workspace. \
  8. Click on identify button if your identification will be wrong for 8 times then it will prompt a new button as identify hint for components. \
  9. After successful identification you need to connect the components with given ports with respective components. \
  10. Point mouse cursor to respective component circle it will become bold then select that circle and drag and drop to the respective component circle. \
  11. Click on check connection button if your connection will be wrong for 8 times then it will prompt a new button as conection hint for components. \
  12. After successful connection click next level button which will appear. \
  13. To open the control valve press actuator symbol so that air will pass through control valve to cylinder and piston will move from left to right end position. \
  14. Once piston will reach to the right end position again press actuator to close the control valve.